✅ Hidden installation, does not affect interior decorationNormally retracted inside the ceiling housing, with no protruding components below the ceiling, suitable for renovated shopping malls, exhibition halls, and corridors, balancing fire protection functionality with spatial aesthetics.
✅ Class A non-combustible inorganic fabric, high temperature resistance and low smoke leakageSilicone-coated inorganic fire-resistant fabric, Class A non-combustible; maintains structural integrity at 620°C, with excellent smoke leakage performance and stable smoke-blocking capability.
✅ Multi-mode fire alarm integration, reliable controlSupports smoke detector linkage, remote control via fire alarm host, and on-site manual button control; automatically deploys on power failure, auto-stops at upper and lower limits, and can send deployment status feedback to the fire alarm host.
✅ Lightweight, large single-span dimensionsFlexible curtain surface is lightweight, placing minimal load on floor slabs; maximum single-section width up to 4000mm, reducing seam joints and minimizing smoke leakage risks.
✅ Wind-resistant, durable and stableCurtain deflection angle ≤15° under 5m/s wind speed; passes 1,000 cycle open-close tests while maintaining normal operation, suitable for long-term repeated use.
✅ Flexible installation, adaptable to piping and conduitsThe flexible fabric allows on-site fine-tuning of openings to avoid ceiling cable trays and ducts, offering higher installation tolerance compared to rigid movable smoke barriers.
Commercial complexes, large supermarkets, office buildings, exhibition centers, underground pedestrian streets, hotel lobbies, airport / metro public areas, renovated underground parking garages, etc.Buildings with aesthetic requirements for ceilings.
Selection Guide: Suitable for projects where ceilings must remain clean and unobstructed, without allowing permanently hanging smoke barriers; for spaces without ceilings or with simple piping layouts, fixed flexible smoke barriers are the preferred choice.
Secure the roller motor unit to the floor slab / beam bottom, install a decorative housing externally, and conceal it within the ceiling;
Attach the curtain surface to the roller, with a weighted bottom bar, and overlap curtain seams by ≥50mm to ensure airtight smoke sealing;
Install manual buttons at a convenient operating height of 1.3~1.5m above the floor;
Connect to the fire alarm system, conduct integrated commissioning, and test lowering, reset, and signal feedback functions;
Upon completion, provide complete fire protection documentation to support fire inspection approval.